  6. 3M™ Cold Shrink QS-III Splice Kit 5418A-750-AL, 1/Case

3M™ Cold Shrink QS-III Splice Kit 5418A-750-AL, 1/Case

  • 3M ID 7100064634
  • UPC 00054007421290

Inline splice for joining jacketed concentric neutral (JCN) and concentric neutral (CN) power cables

Special electrode design of the kit reduces the electrical stress at a critical cable/splice interface

Designed for feeder and distribution circuits, size transition splicing, direct burial installations, submerged locations and use with standard inline crimp connectors

View more details
Frequently viewed resources
PDF (1) Copy 26Safety Data Sheet (PDF, 0B)

Details

Highlights
  • Inline splice for joining jacketed concentric neutral (JCN) and concentric neutral (CN) power cables
  • Special electrode design of the kit reduces the electrical stress at a critical cable/splice interface
  • Designed for feeder and distribution circuits, size transition splicing, direct burial installations, submerged locations and use with standard inline crimp connectors
  • Silicon rubber-splice body provides good high and low temperature performance, and the EPDM rubber jacket offers physical protection
  • Rated for 15 kV class cables
  • Factory-tested partial discharge and AC ensure reliability

3M™ Cold Shrink QS-III Splice Kits are inline splices for joining 25/28 kV jacketed concentric neutral (JCN) or concentric neutral (CN) power cables. It is a cold shrink design.

3M™ Cold Shrink QS-III Splice Kits include a cold shrink splice body in a one-piece moulded design made of specially formulated silicone rubbers, with jacketing made of EPDM rubber for its special physical properties. Each splice is high-voltage production tested to ensure reliability. Kits can be ordered with connectors packed in the kit or the kit and connector can be ordered as separate items. Meets requirements of IEEE 404. Each kit makes one splice. 5456A-WG, 5457A-WG and 5458A-WG are partially jacketed splices containing built-in bleeder wires. Additional end user materials are required to convert to full jacketing. Cable sizes shown below are for standard insulation thickness. Final determining factor is cable insulation O.D.

Suggested applications
  • For inline splicing
  • For feeder and distribution circuits
  • For jacketed concentric neutral cables (JCN)
  • For concentric neutral cables (CN)
  • For copper or aluminum conductors
  • For use with standard inline crimp connectors
  • For size transition splicing
  • For direct burial installations
  • For submerged locations

Typical Properties