3M™ Cold Shrink QT-III Three Conductor Outdoor Termination Kits are skirted and designed for outdoor installations of medium voltage 3/C shielded power cables with internal ground wires. The Hi-K stress control design delivers excellent BIL performance and lower surface stress, resulting in a more compact termination.
The 3M™ Cold Shrink QT-III Three Conductor Outdoor Termination Kit contains one 3M™ Cold Shrink Silicone Rubber Breakout Boot Assembly, one 3M™ Cold Shrink Silicone Rubber Jacket Seal Assembly, three 3M™ Silicone Rubber Phase Re-Jacketing Sleeve Assemblies, three 3M™ Cold Shrink Silicone Rubber Termination Assemblies, one 3M™ Tinned Copper Ground Braid Assembly, three small 3M™ Constant Force Springs, one large 3M™ Constant Force Spring, three 1/2” x 10” (12.7 mm x 254 mm) strips of 3M™ EMI Copper Foil Shielding Tape 1181, eight strips of Scotch® Mastic 2230, one 3/4" (19.05 mm) roll of Scotch® Super 33+™ Vinyl Electrical Tape, one 1-1/2" (25.4-12.7 mm)roll of Scotch® Super Vinyl Electrical Tape 88, one roll of Scotch® Copper Electrical Shielding Tape 24, one 3M™ Cable Cleaning Preparation Kit CC-2, and one Instruction Sheet.
Application/Industry | Industrial Construction |
Applications | Cable Termination |
BIL | 150 kV |
Brands | 3M™ |
Breakout Boot | Yes |
Cable Insulation Outside Diameter Range | 1.18-1.52 in |
Cable Insulation Outside Diameter Range (metric) | 30.0-38.6 mm |
Cable Shielding | Tape Shield, Wire Shield, UniShield® |
Case Quantity | 1 |
Conductor Sizes (Imperial) | 250 kcmil, 300 kcmil, 350 kcmil, 400 kcmil, 500 kcmil, 600 kcmil, 700 kcmil, 750 kcmil, 800 kcmil, 900 kcmil, 1000 kcmil |
Indoor/Outdoor | Outdoor Skirted |
Insulation Level | 100%, 133% |
Insulation Outer Diameter (Imperial) | 1.18 in, 1.19 in, 1.2 in, 1.21 in, 1.22 in, 1.23 in, 1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in, 1.3 in, 1.31 in, 1.32 in, 1.33 in, 1.34 in, 1.35 in, 1.36 in, 1.37 in, 1.38 in, 1.39 in, 1.4 in, 1.41 in, 1.42 in, 1.43 in, 1.44 in, 1.45 in, 1.46 in, 1.47 in, 1.48 in, 1.49 in, 1.5 in, 1.51 in, 1.52 in |
Insulation Outer Diameter (metric) | 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm |
Insulation Rejacketing | Yes |
Lug/Stem Connector Included in Kit | No |
Maximum Cable Outside Diameter | 4.50 Inch |
Maximum Cable Outside Diameter (Metric) | 114.3 mm |
Maximum Installed Length | 12.25 in |
Maximum Installed Length (Metric) | 311 mm |
Number of Conductors | 3 |
Number of Skirts | 4 |
Product Colour | Grey |
Product Series | 7600-S-3G |
Type | Cold Shrink QT-III |
Voltage | 5 kV, 8 kV, 15 kV, 25 kV, 35 kV |
Voltage Application | Medium Voltage |
Safety Data Sheets
Document Number: MSDS_2651776_CA_EN
(PDF)