3M™ Cold Shrink QT-III 7640-T-HSG & 7650-T-HSG Series Termination Kit includes a non-skirted, 1-piece termination. It ensures a pliable, tight seal for tape shield, wire-over-tape shield and longitudinally corrugated shield power cables. The conjunction of high dielectric-constant material and sealing compounds allows the termination to withstand voltages of 5 to 35kV.
Each kit contains: One 3M™ Hi-K Tracking Resistant Silicone Rubber Termination, one 3M™ Pre-Formed High-Ampacity Ground Braid, one 3M™ Constant Force Spring, two Scotch® Mastic Sealing Strips 2230, one 3M™ EMI Copper Foil Shielding Tape 1181, and one Instruction Sheet.
BIL | 150 kV |
Brands | 3M™ |
Breakout Boot | No |
Cable Insulation Outside Diameter Range | 1.53-2.32 in |
Cable Insulation Outside Diameter Range (metric) | 38.9 - 58.9 mm |
Cable Shielding | Longitudinally Corrugated (LC), Wire-Over-Tape Shield, Tape Shield |
Case Quantity | 1 |
Compatible Lug | QL2-A-350-750, QL2-A-500-1000, QL2-A-1000-1250 |
Conductor Sizes (Imperial) | 700 kcmil, 750 kcmil, 800 kcmil, 900 kcmil, 1000 kcmil, 1250 kcmil, 1500 kcmil, 1750 kcmil, 2000 kcmil |
Indoor/Outdoor | Indoor Non-skirted |
Insulation Level | 100%, 133% |
Insulation Outer Diameter (Imperial) | 1.53 in, 1.54 in, 1.55 in, 1.56 in, 1.57 in, 1.58 in, 1.59 in, 1.6 in, 1.61 in, 1.62 in, 1.63 in, 1.64 in, 1.65 in, 1.66 in, 1.67 in, 1.68 in, 1.69 in, 1.7 in, 1.71 in, 1.72 in, 1.73 in, 1.74 in, 1.75 in, 1.76 in, 1.77 in, 1.78 in, 1.79 in, 1.8 in, 1.81 in, 1.82 in, 1.83 in, 1.84 in, 1.85 in, 1.86 in, 1.87 in, 1.88 in, 1.89 in, 1.9 in, 1.91 in, 1.92 in, 1.93 in, 1.94 in, 1.95 in, 1.96 in, 1.97 in, 1.98 in, 1.99 in, 2 in, 2.01 in, 2.02 in, 2.03 in, 2.04 in, 2.05 in, 2.06 in, 2.07 in, 2.08 in, 2.09 in, 2.1 in, 2.11 in, 2.12 in, 2.13 in, 2.14 in, 2.15 in, 2.16 in, 2.17 in, 2.18 in, 2.19 in, 2.2 in, 2.21 in, 2.22 in, 2.23 in, 2.24 in, 2.25 in, 2.26 in, 2.27 in, 2.28 in, 2.29 in, 2.3 in, 2.31 in, 2.32 in |
Insulation Outer Diameter (metric) | 38.862 mm, 39.116 mm, 39.37 mm, 39.624 mm, 39.878 mm, 40.132 mm, 40.386 mm, 40.64 mm, 40.894 mm, 41.148 mm, 41.402 mm, 41.656 mm, 41.91 mm, 42.164 mm, 42.418 mm, 42.672 mm, 42.926 mm, 43.18 mm, 43.434 mm, 43.688 mm, 43.942 mm, 44.196 mm, 44.45 mm, 44.704 mm, 44.958 mm, 45.212 mm, 45.466 mm, 45.72 mm, 45.974 mm, 46.228 mm, 46.482 mm, 46.736 mm, 46.99 mm, 47.244 mm, 47.498 mm, 47.752 mm, 48.006 mm, 48.26 mm, 48.514 mm, 48.768 mm, 49.022 mm, 49.276 mm, 49.53 mm, 49.784 mm, 50.038 mm, 50.292 mm, 50.546 mm, 50.8 mm, 51.054 mm, 51.308 mm, 51.562 mm, 51.816 mm, 52.07 mm, 52.324 mm, 52.578 mm, 52.832 mm, 53.086 mm, 53.34 mm, 53.594 mm, 53.848 mm, 54.102 mm, 54.356 mm, 54.61 mm, 54.864 mm, 55.118 mm, 55.372 mm, 55.626 mm, 55.88 mm, 56.134 mm, 56.388 mm, 56.642 mm, 56.896 mm, 57.15 mm, 57.404 mm, 57.658 mm, 57.912 mm, 58.166 mm, 58.42 mm, 58.674 mm, 58.928 mm |
Insulation Rejacketing | No |
Lug/Stem Connector Included in Kit | No |
Maximum Installed Length | 16.00 in |
Number of Conductors | 1 |
Number of Skirts | 0 |
Product Series | 7650-T-HSG, 7650-T-HSG-150 |
Voltage | 5 kV, 8 kV, 15 kV, 25 kV, 35 kV |
Voltage Application | Medium Voltage |