1. Canada
  2. All 3M Products
  3. Electrical
  4. Splices & Accessories
  5. Cold Shrink Splices
  6. 3M™ Cold Shrink Foldback Splice Jacket Kit, SJ-1FB, 15 kV

3M™ Cold Shrink Foldback Splice Jacket Kit, SJ-1FB, 15 kV

  • 3M ID 7000140752
  • UPC 00051128553022

Easy to install—simply position over one mastic cable seal and shrink to the other as directed

No torches or heat required

Seals tight, retains its resiliency and pressure even after years of aging and exposure

View more details
Frequently viewed resources
PDF (1) Copy 26Safety Data Sheet (PDF)

Details

Highlights
  • Easy to install—simply position over one mastic cable seal and shrink to the other as directed
  • No torches or heat required
  • Seals tight, retains its resiliency and pressure even after years of aging and exposure
  • Versatile one-piece jacket that accommodates a wide range of cable sizes and splice diameters
  • Tough rubber formulation to withstand rough back filling
  • Water resistant
  • Resists fungus, acids, alkalies, ozone and ultraviolet light

3M™ Cold Shrink Foldback Splice Jacket Kits SJ-FB Series are a series of folded back, tubular rubber sleeves that provide a sealed jacket over cable splices installed on jacketed concentric neutral (JCN) and other types of jacketed power cable when combined with Scotch® Rubber Mastic Tape 2228. The jacketing tube is made from EPDM rubber that contains no chlorides or sulfurs.

3M™ SJ Cold Shrink Foldback Splice Jacket Kit contains a cold shrink foldback jacket tube, rolls of rubber mastic tape and mastic strips. The mastic tape offers an assured sealing interface between the cable jacket and cold shrink foldback jacket tube. The mastic strip seals around the optional, external ground conductor. The cold shrink jacket tube is made from chloride and sulfur free EPDM rubber. The seamless rubber tube from cable jacket to cable jacket minimizes sealing steps and moisture ingress paths.

Suggested applications
  • To jacket inline splices installed on Jacketed Concentric Neutral (JCN) Cables rated at 15, 25 and 35 kV
  • For use at indoor and outdoor installations including direct burial, aerial and submersible applications
  • Physical protection and moisture sealing inline splices installed on shielded power cables having solid dielectric insulation as follows: polyethylene (high and low density), cross-linked polyethylene (XLP) and ethylene propylene rubber (EPR)

Typical Properties

Applications

Cable Connection

Brands

3M™

Cable Shielding

Jacketed Concentric Neutral (JCN)

Conductor Material

Copper, Aluminum

Conductor Sizes (Imperial)

1 AWG

Conductor Sizes (Metric)

50 mm²

Insulation Outer Diameter (Imperial)

0.95 in, 0.96 in, 0.97 in, 0.98 in, 0.99 in, 1 in, 1.01 in, 1.02 in, 1.03 in, 1.04 in, 1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in, 1.13 in, 1.14 in, 1.15 in, 1.16 in, 1.17 in, 1.18 in, 1.19 in, 1.2 in, 1.21 in, 1.22 in, 1.23 in, 1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in, 1.3 in, 1.31 in, 1.32 in, 1.33 in, 1.34 in, 1.35 in, 1.36 in, 1.37 in, 1.38 in, 1.39 in, 1.4 in, 1.41 in, 1.42 in, 1.43 in, 1.44 in, 1.45 in, 1.46 in, 1.47 in, 1.48 in, 1.49 in, 1.5 in, 1.51 in, 1.52 in, 1.53 in, 1.54 in, 1.55 in, 1.56 in, 1.57 in, 1.58 in, 1.59 in, 1.6 in, 1.61 in, 1.62 in, 1.63 in, 1.64 in, 1.65 in, 1.66 in, 1.67 in, 1.68 in, 1.69 in, 1.7 in, 1.71 in, 1.72 in, 1.73 in, 1.74 in, 1.75 in, 1.76 in, 1.77 in, 1.78 in, 1.79 in, 1.8 in, 1.81 in, 1.82 in, 1.83 in, 1.84 in, 1.85 in, 1.86 in, 1.87 in, 1.88 in, 1.89 in, 1.9 in, 1.91 in, 1.92 in, 1.93 in, 1.94 in, 1.95 in, 1.96 in, 1.97 in, 1.98 in, 1.99 in, 2 in

Insulation Outer Diameter (metric)

24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm, 38.862 mm, 39.116 mm, 39.37 mm, 39.624 mm, 39.878 mm, 40.132 mm, 40.386 mm, 40.64 mm, 40.894 mm, 41.148 mm, 41.402 mm, 41.656 mm, 41.91 mm, 42.164 mm, 42.418 mm, 42.672 mm, 42.926 mm, 43.18 mm, 43.434 mm, 43.688 mm, 43.942 mm, 44.196 mm, 44.45 mm, 44.704 mm, 44.958 mm, 45.212 mm, 45.466 mm, 45.72 mm, 45.974 mm, 46.228 mm, 46.482 mm, 46.736 mm, 46.99 mm, 47.244 mm, 47.498 mm, 47.752 mm, 48.006 mm, 48.26 mm, 48.514 mm, 48.768 mm, 49.022 mm, 49.276 mm, 49.53 mm, 49.784 mm, 50.038 mm, 50.292 mm, 50.546 mm, 50.8 mm

Maximum Cable Jacket Opening

25 Inch

Maximum Splice O.D.

2.00 Inch

Maximum Splice Outside Diameter

2 in

Maximum Splice Outside Diameter (Metric)

50.8

Minimum Cable Jacket O.D.

0.95 in

Product Colour

Black

Splice Type

Inline

Units per Case

6.0

Voltage

15 kV

Resources

Safety Data Sheets

Document Number: MSDS_1946409_CA_EN

(PDF)