3M™ Cold Shrink QT-III Silicone Rubber Terminations are a one-piece, non-skirted silicone rubber termination that comes with factory-applied, pre-positioned Hi-K stress control layers underneath the insulator. Its short installed length is excellent for installations in limited spaces, such as those with motors, starters, switchgear, variable speed drives, transformers and similar connections which often reduce the need to add auxiliary boxes when enclosure space is limited. The 3M™ Cold Shrink QT-III Silicone Rubber Termination 7664-S-8 has a conductor size range for 5 kV: 500-750 kcmil, 8 kV: 350-700 kcmil, 15 kV: 4/0 AWG-500 kcmil, 25/28 kV: 2/0 AWG-250 kcmil and 35 kV: 2-4/0 AWG.
Each kit contains: One 3M™ Hi-K Tracking Resistant Silicone Rubber Termination, two Scotch® Mastic Sealing Strips 2230, and one Instruction Sheet.
BIL | 200 kV |
Brands | 3M™ |
Breakout Boot | No |
Cable Insulation Outside Diameter Range | 0.83-1.53 in |
Cable Insulation Outside Diameter Range (metric) | 21.1 - 38.9 mm |
Cable Shielding | Concentric Neutral (CN), Jacketed Concentric Neutral (JCN) |
Case Quantity | 1 |
Compatible Lug | QL2-A-2-250, QL2-A-1/0-350, QL2-A-4/0-600 |
Conductor Sizes (Imperial) | 1 AWG, 2 AWG, 1/0 AWG, 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil, 300 kcmil, 350 kcmil, 400 kcmil, 500 kcmil, 600 kcmil, 700 kcmil, 750 kcmil |
Indoor/Outdoor | Outdoor Skirted |
Insulation Level | 100%, 133% |
Insulation Outer Diameter (Imperial) | 0.83 in, 0.84 in, 0.85 in, 0.86 in, 0.87 in, 0.88 in, 0.89 in, 0.9 in, 0.91 in, 0.92 in, 0.93 in, 0.94 in, 0.95 in, 0.96 in, 0.97 in, 0.98 in, 0.99 in, 1 in, 1.01 in, 1.02 in, 1.03 in, 1.04 in, 1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in, 1.13 in, 1.14 in, 1.15 in, 1.16 in, 1.17 in, 1.18 in, 1.19 in, 1.2 in, 1.21 in, 1.22 in, 1.23 in, 1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in, 1.3 in, 1.31 in, 1.32 in, 1.33 in, 1.34 in, 1.35 in, 1.36 in, 1.37 in, 1.38 in, 1.39 in, 1.4 in, 1.41 in, 1.42 in, 1.43 in, 1.44 in, 1.45 in, 1.46 in, 1.47 in, 1.48 in, 1.49 in, 1.5 in, 1.51 in, 1.52 in, 1.53 in |
Insulation Outer Diameter (metric) | 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm, 38.862 mm |
Insulation Rejacketing | No |
Lug/Stem Connector Included in Kit | No |
Maximum Installed Length | 20.50 in |
Number of Conductors | 1 |
Number of Skirts | 8 |
Product Series | 7660-S |
Termination Type | Single Termination |
Units per Case | 1.0 |
Voltage | 5 kV, 8 kV, 15 kV, 25 kV, 35 kV |
Voltage Application | Medium Voltage |
Safety Data Sheets
Document Number: MSDS_3625902_CA_EN
(PDF)