1. Canada
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-III Termination Kit, 7655-T-150, CN and JCN Cable, Non-Skirted High Amp, 5-35 kV, 1.05-1.80 in (26.7-45.7 mm) Cable Insul. O.D., 1 termination/kit

3M™ Cold Shrink QT-III Termination Kit, 7655-T-150, CN and JCN Cable, Non-Skirted High Amp, 5-35 kV, 1.05-1.80 in (26.7-45.7 mm) Cable Insul. O.D., 1 termination/kit

  • 3M ID 7000140705
  • UPC 00054007417743

Quick installation with versatile one-piece design

No torches, heat or special tools required

Hi-K stress control

View more details
Frequently viewed resources
PDF (1) Copy 26Safety Data Sheet (PDF)

Details

Highlights
  • Quick installation with versatile one-piece design
  • No torches, heat or special tools required
  • Hi-K stress control
  • Excellent tracking resistance
  • Includes everything required to make one single phase termination (except lug)

3M™ Cold Shrink QT-III 7640-T-HSG & 7650-T-HSG Series Termination Kits includes a non-skirted, one-piece termination. It ensures a pliable, tight seal for tape shield, wire-over-tape shield and longitudinally corrugated shield power cables. The conjunction of high dielectric-constant material and sealing compounds allows the termination to withstand voltages of 5 to 35kV.

Each kit contains: one High-K , Tracking Resistant, Silicone Rubber Termination, two 2 strips Scotch® Mastic Strip 2230 (black with white release liners, bagged) and one instruction sheet

Suggested applications
  • Terminating solid dielectric Jacketed Concentric Neutral (JCN) and Concentric Neutral (CN) power cables
  • Designed for solid dielectric insulations, such as polyethylene, XLPE and EPR
  • Free-hanging or bracket-mounting arrangements
  • Compact design provides for easier installation in restricted spaces
  • Switchgear, transformer, motor lead, bus and similar connections

Typical Properties

BIL

150 kV

Brands

3M™

Breakout Boot

No

Cable Insulation Outside Diameter Range

1.05-1.80 in

Cable Insulation Outside Diameter Range (metric)

26.7 - 45.7 mm

Cable Shielding

Concentric Neutral (CN), Jacketed Concentric Neutral (JCN)

Case Quantity

1

Compatible Lug

QL2-A-4/0-600, QL2-A-350-750

Conductor Sizes (Imperial)

3/0 AWG, 4/0 AWG, 250 kcmil, 300 kcmil, 350 kcmil, 400 kcmil, 450 kcmil, 500 kcmil, 600 kcmil, 700 kcmil, 750 kcmil, 800 kcmil, 900 kcmil, 1000 kcmil, 1250 kcmil, 1500 kcmil

Indoor/Outdoor

Indoor Non-skirted

Insulation Level

100%, 133%

Insulation Outer Diameter (Imperial)

1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in, 1.13 in, 1.14 in, 1.15 in, 1.16 in, 1.17 in, 1.18 in, 1.19 in, 1.2 in, 1.21 in, 1.22 in, 1.23 in, 1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in, 1.3 in, 1.31 in, 1.32 in, 1.33 in, 1.34 in, 1.35 in, 1.36 in, 1.37 in, 1.38 in, 1.39 in, 1.4 in, 1.41 in, 1.42 in, 1.43 in, 1.44 in, 1.45 in, 1.46 in, 1.47 in, 1.48 in, 1.49 in, 1.5 in, 1.51 in, 1.52 in, 1.53 in, 1.54 in, 1.55 in, 1.56 in, 1.57 in, 1.58 in, 1.59 in, 1.6 in, 1.61 in, 1.62 in, 1.63 in, 1.64 in, 1.65 in, 1.66 in, 1.67 in, 1.68 in, 1.69 in, 1.7 in, 1.71 in, 1.72 in, 1.73 in, 1.74 in, 1.75 in, 1.76 in, 1.77 in, 1.78 in, 1.79 in, 1.8 in

Insulation Outer Diameter (metric)

26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm, 38.862 mm, 39.116 mm, 39.37 mm, 39.624 mm, 39.878 mm, 40.132 mm, 40.386 mm, 40.64 mm, 40.894 mm, 41.148 mm, 41.402 mm, 41.656 mm, 41.91 mm, 42.164 mm, 42.418 mm, 42.672 mm, 42.926 mm, 43.18 mm, 43.434 mm, 43.688 mm, 43.942 mm, 44.196 mm, 44.45 mm, 44.704 mm, 44.958 mm, 45.212 mm, 45.466 mm, 45.72 mm

Insulation Rejacketing

No

Lug/Stem Connector Included in Kit

No

Material

Silicone Rubber

Maximum Installed Length

16.00 in

Number of Conductors

1

Product Series

7650-T-150

Voltage

5 kV, 8 kV, 15 kV, 25 kV, 35 kV

Voltage Application

Medium Voltage

Resources