  6. 3M™ Cold Shrink QT-III Three Conductor Indoor Termination Kit, 7623-T-95-3G, 8.7 kV, 0.70-0.92 in (17.8-23.4 mm) cable insulation O.D., 3 terminations per kit

3M™ Cold Shrink QT-III Three Conductor Indoor Termination Kit, 7623-T-95-3G, 8.7 kV, 0.70-0.92 in (17.8-23.4 mm) cable insulation O.D., 3 terminations per kit

  • 3M ID 7000133179
  • UPC 00054007436669

Quick installation with versatile one-piece design

No torches, heat or special tools required

Hi-K stress control

View more details
Frequently viewed resources
PDF (1) Copy 26Safety Data Sheet (PDF)

Details

Highlights
  • Quick installation with versatile one-piece design
  • No torches, heat or special tools required
  • Hi-K stress control
  • Excellent tracking resistance
  • Includes everything required to make 3 terminations (except lugs)
  • Also includes Rejacketing Sleeve Assembly and Breakout boot
  • Conductor size ranges: 5 kV (100%): 4/0 AWG-350 kcmil, 5 kV (133%): 3/0 AWG-350 kcmil, 8 kV (100% or 133%): 3/0 AWG-350 kcmil

3M™ Cold Shrink QT-III, Three Conductor Termination Kit 7600-T-3G is tubular and designed for cables with internal ground wires for indoor installations. The Hi-K stress control design delivers excellent BIL performance and lower surface stress, resulting in a more compact termination.

Each kit contains: One 3M™ Cold Shrink Silicone Rubber Breakout Boot Assembly, one 3M™ Cold Shrink Silicone Rubber Jacket Seal Assembly, three 3M™ Silicone Rubber Phase Rejacketing Sleeve Assemblies, three 3M™ Cold Shrink Silicone Rubber Termination Assemblies, one 3M™ Tinned Copper Ground Braid Assembly, three small 3M™ Constant-Force Springs, one large 3M™ Constant-Force Spring, eight strips of Scotch® Mastic 2230, one 3/4" (19.05 mm) roll of Scotch® Super 33+™ Vinyl Electrical Tape, one 1-1/2" (25.4-12.7 mm) roll Scotch® Vinyl Electrical Tape Super 88, one roll of Scotch® Electrical Shielding Tape 24, one 3M™ Cable Cleaning Preparation Kit CC-2, three 1/2" x 10" (12.7 mm x 254 mm) strips of 3M™ EMI Copper Foil Shielding Tape 1181, and one Instruction Sheet.

Suggested applications
  • Terminating solid dielectric shielded power cable
  • Tape shielded cable (armored or unarmored)
  • Free-hanging or bracket-mounting arrangements
  • Compact design provides for easier installation in restricted spaces
  • For cables with internal ground wires
  • *For Wire and Unishield® cables please contact your 3M representative for technical assistance

Typical Properties

Applications

Cable Connection

BIL

95 kV

Brands

3M™

Breakout Boot

Yes

Cable Insulation Outside Diameter Range

0.70-0.92 in

Cable Insulation Outside Diameter Range (metric)

17.8-23.4 mm

Cable Shielding

Tape Shield, UniShield®, Wire-Over-Tape Shield, Wire Shield

Case Quantity

1

Conductor Material

Aluminum, Copper

Conductor Sizes (Imperial)

3/0 AWG, 4/0 AWG, 250 kcmil, 300 kcmil, 350 kcmil, 500 kcmil, 750 kcmil, 1000 kcmil

Connector Included

None

Indoor/Outdoor

Indoor Non-skirted

Insulation Level

100%, 133%

Insulation Outer Diameter (Imperial)

0.7 in, 0.71 in, 0.72 in, 0.73 in, 0.74 in, 0.75 in, 0.76 in, 0.77 in, 0.78 in, 0.79 in, 0.8 in, 0.81 in, 0.82 in, 0.83 in, 0.84 in, 0.85 in, 0.86 in, 0.87 in, 0.88 in, 0.89 in, 0.9 in, 0.91 in, 0.92 in

Insulation Outer Diameter (metric)

17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm

Insulation Outside Diameter Range

1.08 - 1.70 Inch

Insulation Outside Diameter Range (metric)

27.4 - 43.2 mm

Insulation Rejacketing

Yes

Lug/Stem Connector Included in Kit

No

Maximum Cable Outside Diameter

3.30 in

Maximum Cable Outside Diameter (Metric)

83.8 mm

Maximum Conductor Size (Imperial)

1000 kcmil

Maximum Conductor Size (Metric)

500 mm²

Maximum Installed Length

8.50 in

Minimum Conductor Size (Imperial)

500 kcmil

Minimum Conductor Size (Metric)

240 mm²

Number of Conductors

3

Product Series

7600-T-3G

Product Type

Splice

Splice Type

Inline

Suitable for High Voltage

No

Typical Splice Length

32 in

Typical Splice Length (metric)

813 mm

Units per Case

1.0

Voltage

5 kV, 8 kV, 15 kV, 25 kV, 35 kV

Voltage Application

Medium Voltage

Resources

Safety Data Sheets

Document Number: MSDS_2654440_CA_EN

(PDF)