  6. 3M™ Cold Shrink QT-III Inverted Outdoor Termination Kit, 7653-S-INV-4, CN and JCN Cable, 5-35 kV, 0.72-1.29 in (18.3-32.8 mm) cable insulation O.D., 1 termination per kit

3M™ Cold Shrink QT-III Inverted Outdoor Termination Kit, 7653-S-INV-4, CN and JCN Cable, 5-35 kV, 0.72-1.29 in (18.3-32.8 mm) cable insulation O.D., 1 termination per kit

  • 3M ID 7000132780
  • UPC 00054007046257

Quick installation with versatile one-piece design

No torches, heat or special tools required

Hi-K stress control

View more details

Details

Highlights
  • Quick installation with versatile one-piece design
  • No torches, heat or special tools required
  • Hi-K stress control
  • Excellent tracking resistance, UV resistance and water-shedding properties
  • Includes everything required to make one single phase termination (except lug)

3M™ Cold Shrink QT-III 7640-S-INV & 7650-S-INV Series Inverted Termination Kit includes a single-conductor, skirted termination. It ensures a pliable, tight seal for jacketed concentric neutral and concentric neutral power cables. The conjunction of high dielectric-constant material and sealing compounds allows the termination to withstand voltages of 5 to 35kV.

Each kit contains: One 3M™ Hi-K Tracking Resistant Silicone Rubber Termination, two Scotch® Mastic Sealing Strips 2230, and one Instruction Sheet.

Suggested applications
  • Terminating solid dielectric Jacketed Concentric Neutral (JCN) and Concentric Neutral (CN) power cables
  • Designed for solid dielectric insulations, such as polyethylene, XLPE and EPR
  • Free-hanging or bracket-mounting arrangements
  • Compact design provides for easier installation in restricted spaces
  • For inverted installations
  • For outdoor use

Typical Properties

BIL

200 kV

Brands

3M™

Breakout Boot

No

Cable Insulation Outside Diameter Range

0.72-1.29 in

Cable Insulation Outside Diameter Range (metric)

18.3-32.8 mm

Cable Shielding

Concentric Neutral (CN), Jacketed Concentric Neutral (JCN)

Case Quantity

1

Compatible Lug

QL2-A-2-250

Conductor Sizes (Imperial)

1 AWG, 2 AWG, 1/0 AWG, 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil, 300 kcmil, 350 kcmil, 400 kcmil, 450 kcmil, 500 kcmil

Indoor/Outdoor

Outdoor

Insulation Level

100%, 133%

Insulation Outer Diameter (Imperial)

0.72 in, 0.73 in, 0.74 in, 0.75 in, 0.76 in, 0.77 in, 0.78 in, 0.79 in, 0.8 in, 0.81 in, 0.82 in, 0.83 in, 0.84 in, 0.85 in, 0.86 in, 0.87 in, 0.88 in, 0.89 in, 0.9 in, 0.91 in, 0.92 in, 0.93 in, 0.94 in, 0.95 in, 0.96 in, 0.97 in, 0.98 in, 0.99 in, 1 in, 1.01 in, 1.02 in, 1.03 in, 1.04 in, 1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in, 1.13 in, 1.14 in, 1.15 in, 1.16 in, 1.17 in, 1.18 in, 1.19 in, 1.2 in, 1.21 in, 1.22 in, 1.23 in, 1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in

Insulation Outer Diameter (metric)

18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm

Insulation Rejacketing

No

Maximum Installed Length

16.00 in

Number of Conductors

1

Number of Skirts

4

Product Series

7650-S-INV

Voltage

5 kV, 8 kV, 15 kV, 35 kV, 25/28 kV

Voltage Application

Medium Voltage

mgctlbxN$MZP mgctlbxV$5.3.6 mgctlbxL$C