1. Canada
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-II Silicone Rubber Termination Kit 5612A, Non-Shielded, 3/Kit

3M™ Cold Shrink QT-II Silicone Rubber Termination Kit 5612A, Non-Shielded, 3/Kit

  • 3M ID 7000132470
  • UPC 00054007495505

Track-resistant silicone rubber insulators with built-in Hi-K stress relief

Easy installation; insulators are pre-stretched around a spiral-wound, plastic core

Void-free, flexible seal without special tools or torches

View more details
Frequently viewed resources
PDF (1) Copy 26Safety Data Sheet (PDF)

Details

Highlights
  • Track-resistant silicone rubber insulators with built-in Hi-K stress relief
  • Easy installation; insulators are pre-stretched around a spiral-wound, plastic core
  • Void-free, flexible seal without special tools or torches
  • Each kit contains material needed to seal three cable ends (except lugs)
  • Includes 3 non-skirted, single-conductor, cold shrink terminations

The 3M™ Cold Shrink QT-II Silicone Rubber Termination Kit will terminate 1/C non-shielded cables. It can be used for both indoor (protected) and outdoor (weather-exposed) applications.

3M™ Cold Shrink QT-II Silicone Rubber Termination Kits are designed for terminating medium voltage cables in both indoor and weather-exposed outdoor applications. The track resistant, silicone rubber insulation of the termination has a hydrophobic property and offers a long-lasting service life while minimizing leakage currents in wet conditions.

Suggested applications
  • For terminating single conductor non-shielded cables
  • For both indoor (protected) and outdoor (weather-exposed) applications

Typical Properties

Applications

Cable Termination

Brands

3M™

Breakout Boot

No

Cable Insulation Outside Diameter Range

0.44-0.95 in

Cable Insulation Outside Diameter Range (metric)

11.2-24.1 mm

Cable Shielding

Non-shielded

Case Quantity

1

Conductor Sizes (Imperial)

1 AWG, 2 AWG, 1/0 AWG, 2/0 AWG

Indoor/Outdoor

Indoor Non-skirted

Insulation Level

100%, 133%

Insulation Outer Diameter (Imperial)

0.44 in, 0.45 in, 0.46 in, 0.47 in, 0.48 in, 0.49 in, 0.5 in, 0.51 in, 0.52 in, 0.53 in, 0.54 in, 0.55 in, 0.56 in, 0.57 in, 0.58 in, 0.59 in, 0.6 in, 0.61 in, 0.62 in, 0.63 in, 0.64 in, 0.65 in, 0.66 in, 0.67 in, 0.68 in, 0.69 in, 0.7 in, 0.71 in, 0.72 in, 0.73 in, 0.74 in, 0.75 in, 0.76 in, 0.77 in, 0.78 in, 0.79 in, 0.8 in, 0.81 in, 0.82 in, 0.83 in, 0.84 in, 0.85 in, 0.86 in, 0.87 in, 0.88 in, 0.89 in, 0.9 in, 0.91 in, 0.92 in, 0.93 in, 0.94 in, 0.95 in, 1.12 in

Insulation Outer Diameter (metric)

11.176 mm, 11.43 mm, 11.684 mm, 11.938 mm, 12.192 mm, 12.446 mm, 12.7 mm, 12.954 mm, 13.208 mm, 13.462 mm, 13.716 mm, 13.97 mm, 14.224 mm, 14.478 mm, 14.732 mm, 14.986 mm, 15.24 mm, 15.494 mm, 15.748 mm, 16.002 mm, 16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm

Insulation Rejacketing

No

Lug/Stem Connector Included in Kit

No

Material

Silicone Rubber

Maximum Conductor Size (Imperial)

2/0 AWG

Maximum Conductor Size (Metric)

70 mm²

Maximum Installed Length

8.00 in

Minimum Conductor Size (Imperial)

2 AWG

Minimum Conductor Size (Metric)

35 mm²

Number of Conductors

1

Product Series

5610A

Voltage

5 kV, 8 kV

Resources

Safety Data Sheets

Document Number: MSDS_2642973_CA_EN

(PDF)