Splices shielded cables

Silicon rubber-splice body provides good high- or low-temperature performance and Armorcast jacket offers mechanical protection

Suitable for use with 10000 and 20000 Series connectors or other UL Listed inline compression connectors

View more details
Frequently viewed resources
PDF (1) Copy 26Safety Data Sheet (PDF)

Details

Highlights
  • Splices shielded cables
  • Silicon rubber-splice body provides good high- or low-temperature performance and Armorcast jacket offers mechanical protection
  • Suitable for use with 10000 and 20000 Series connectors or other UL Listed inline compression connectors
  • Solderless ground braid offers constant force spring connection
  • Rated for 35 kV applications

3M™ Cold Shrink QS-III 3/C Armoured or Non-Armoured Splice Kits 5797A-MT and 5798A-MT Series are designed for splicing 3/C, Armoured and nonArmoured, shielded power cables. The kits are rated for use on 35 kV cables with conductor sizes from 1/0 AWG-1000 kcmil (60-500 mm²).

The 3M™ Cold Shrink QS-III 3/C Armoured or Non-Armoured Splice Kits are designed to be used with 3M™ Scotchlok™ Connectors 10000 and 20000 Series or other UL listed inline compression connectors that fit within the dimension limits listed in the Connector Dimensional Requirements Table on the data sheet. The splice utilizes several technologies to accommodate the various functions of a 3/C shielded power cable: 3M™ Cold Shrink QS-III Splice Bodies, Scotch® brand tapes for moisture sealing, Constant Force Springs for connecting ground braid jumpers and 3M™ Armorcast Structural Material for replacing the cable armour and/or jacket. The completed splice is designed for use in cable trays, weather-exposed or direct burial locations. Meets the requirements of IEEE 404. Connectors are not included in the kit and must be ordered separately. Note: When making a trifurcating splice, the 3M™ Cold Shrink MT-E Trifurcating Accessory Kit must be used along with the splice kit. Note: Cable sizes shown below are for standard insulation thickness. Final determining factor is cable insulation O.D.

Suggested applications
  • For inline splicing
  • For armoured and non-armoured cables
  • For 35 kV rated cables
  • For cable conductor size range of 1/0 AWG to 1000 kcmil
  • For use with solid dielectric cables; XLP, XLPE, EPR, etc
  • For indoor and outdoor applications: Cable Tray; Cable Rack; Cable Hangers; Junction Box; Aerial; and Wet or dry locations

Typical Properties

Brands

3M™

Cable Shielding

Non-Armored Shielded, Shielded Armored

Conductor Material

Copper, Aluminum

Conductor Sizes (Imperial)

350 kcmil, 400 kcmil, 500 kcmil, 600 kcmil, 700 kcmil, 750 kcmil, 800 kcmil, 900 kcmil, 1000 kcmil

Insulation Level

1.33, 100%, 133%

Insulation Outer Diameter (Imperial)

1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in, 1.3 in, 1.31 in, 1.32 in, 1.33 in, 1.34 in, 1.35 in, 1.36 in, 1.37 in, 1.38 in, 1.39 in, 1.4 in, 1.41 in, 1.42 in, 1.43 in, 1.44 in, 1.45 in, 1.46 in, 1.47 in, 1.48 in, 1.49 in, 1.5 in, 1.51 in, 1.52 in, 1.53 in, 1.54 in, 1.55 in, 1.56 in, 1.57 in, 1.58 in, 1.59 in, 1.6 in, 1.61 in, 1.62 in, 1.63 in, 1.64 in, 1.65 in, 1.66 in, 1.67 in, 1.68 in, 1.69 in, 1.7 in, 1.71 in, 1.72 in, 1.73 in, 1.74 in, 1.75 in, 1.76 in, 1.77 in, 1.78 in, 1.79 in, 1.8 in, 1.81 in, 1.82 in, 1.83 in, 1.84 in, 1.85 in, 1.86 in, 1.87 in, 1.88 in, 1.89 in, 1.9 in, 1.91 in, 1.92 in, 1.93 in, 1.94 in, 1.95 in, 1.96 in, 1.97 in, 1.98 in, 1.99 in, 2 in, 2.01 in, 2.02 in, 2.03 in, 2.04 in, 2.05 in, 2.06 in, 2.07 in

Number of Conductors

3

Splice Type

Cold Shrink

Voltage

35 kV

Resources

Safety Data Sheets

Document Number: MSDS_2650224_CA_EN

(PDF)