3M™ Cold Shrink QT-II Silicone Rubber Termination Kits QT-II 5670 Series will terminate CN or JCN cables and can be used for both indoor (protected) and outdoor (weather-exposed) applications.
Each 3M™ Cold Shrink QT-II Silicone Rubber Termination Kit QT-II 5670 Series includes one each of: Hi-K silicone rubber termination, Silicone rubber terminator, Packet of silicone grease and Instruction sheet
Applications | Cable Termination |
BIL | 110 kV |
Brands | 3M™ |
Breakout Boot | No |
Cable Insulation Outside Diameter Range | 0.64 to 1.12 in |
Cable Insulation Outside Diameter Range (metric) | 16.2-28.4 mm |
Cable Shielding | Concentric Neutral (CN), Jacketed Concentric Neutral (JCN) |
Cable Type | Polymeric insulated, copper wire screened, unarmored cable |
Case Quantity | 10 |
Conductor Sizes (Imperial) | 1 AWG, 2 AWG, 1/0 AWG, 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil |
Indoor/Outdoor | Indoor Non-skirted |
Insulation Level | 100%, 133% |
Insulation O.D. Range (Metric) | 16.2-28.4 mm |
Insulation Outer Diameter (Imperial) | 0.64 in, 0.65 in, 0.66 in, 0.67 in, 0.68 in, 0.69 in, 0.7 in, 0.71 in, 0.72 in, 0.73 in, 0.74 in, 0.75 in, 0.76 in, 0.77 in, 0.78 in, 0.79 in, 0.8 in, 0.81 in, 0.82 in, 0.83 in, 0.84 in, 0.85 in, 0.86 in, 0.87 in, 0.88 in, 0.89 in, 0.9 in, 0.91 in, 0.92 in, 0.93 in, 0.94 in, 0.95 in, 0.96 in, 0.97 in, 0.98 in, 0.99 in, 1 in, 1.01 in, 1.02 in, 1.03 in, 1.04 in, 1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in |
Insulation Outer Diameter (metric) | 16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm |
Insulation Rejacketing | No |
Lug/Stem Connector Included in Kit | No |
Material | Silicone Rubber |
Maximum Conductor Size (Imperial) | 500 kcmil |
Maximum Conductor Size (Metric) | 240 mm² |
Maximum Installed Length | 6.25 in |
Minimum Conductor Size (Imperial) | 2/0 AWG |
Minimum Conductor Size (Metric) | 70 mm² |
Number of Conductors | 1 |
Product Colour | Grey |
Product Series | 5670 |
Voltage | 15 kV |
Voltage Rating | 6/10 kV |
Safety Data Sheets
Document Number: MSDS_2632586_CA_EN
(PDF)