1. Canada
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-III Three Conductor Cable Termination Kit, 7624-T-95-3G, tape, wire and UniShield®, 8.7 kV, 0.92-1.18 in cable insul. O.D., 3 terminations per kit

3M™ Cold Shrink QT-III Three Conductor Cable Termination Kit, 7624-T-95-3G, tape, wire and UniShield®, 8.7 kV, 0.92-1.18 in cable insul. O.D., 3 terminations per kit

  • 3M ID 7000031772
  • UPC 00054007436676

Quick installation with versatile one-piece design

No torches, heat or special tools required

Hi-K stress control

View more details
Frequently viewed resources
PDF (1) Copy 26Safety Data Sheet (PDF)

Details

Highlights
  • Quick installation with versatile one-piece design
  • No torches, heat or special tools required
  • Hi-K stress control
  • Excellent tracking resistance
  • Includes everything required to make 3 terminations (except lugs)
  • Also includes Rejacketing Sleeve Assembly and Breakout boot
  • Conductor size ranges: 5 kV (100%): 4/0 AWG-350 kcmil, 5 kV (133%): 3/0 AWG-350 kcmil, 8 kV (100% or 133%): 3/0 AWG-350 kcmil, 15 kV (100%): 1/0-4/0 AWG, 15 kV (133%): 2-3/0 AWG, 25/28 kV (100%): 1-1/0 AWG

3M™ Cold Shrink QT-III 7600-T-3G Series Termination Kit includes a non-skirted, 3-phase termination. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The silicone rubber sealing compounds allow the termination to withstand voltages of 5 to 35kV.

Each kit contains: One 3M™ Cold Shrink Silicone Rubber Breakout Boot Assembly, one 3M™ Cold Shrink Silicone Rubber Jacket Seal Assembly, three 3M™ Silicone Rubber Phase Rejacketing Sleeve Assemblies, three 3M™ Cold Shrink Silicone Rubber Termination Assemblies, one 3M™ Tinned Copper Ground Braid Assembly, three small 3M™ Constant-Force Springs, one large 3M™ Constant-Force Spring, eight strips of Scotch® Mastic 2230, one 3/4" (19.05 mm) roll of Scotch® Super 33+™ Vinyl Electrical Tape, one 1-1/2" (25.4-12.7 mm) roll of Scotch® Vinyl Electrical Tape Super 88, one roll of Scotch® Electrical Shielding Tape 24, one 3M™ Cable Cleaning Preparation Kit CC-2, three 1/2" x 10" (12.7 mm x 254 mm) strips of 3M™ EMI Copper Foil Shielding Tape 1181, and one Instruction Sheet.

Suggested applications
  • Terminating solid dielectric shielded power cable
  • Tape shielded cable (armored or unarmored)
  • Free-hanging or bracket-mounting arrangements
  • Compact design provides for easier installation in restricted spaces
  • For cables with internal ground wires
  • *For Wire and Unishield® cables please contact your 3M representative for technical assistance

Typical Properties

BIL

95 kV

Brands

3M™

Breakout Boot

Yes

Cable Insulation Outside Diameter Range

0.92-1.18 in

Cable Insulation Outside Diameter Range (metric)

23.4-30.0 mm

Cable Shielding

Tape Shield, Wire Shield, UniShield®

Case Quantity

1

Conductor Sizes (Imperial)

400 kcmil, 500 kcmil

Indoor/Outdoor

Indoor Non-skirted

Insulation Level

100%, 133%

Insulation Outer Diameter (Imperial)

0.92 in, 0.93 in, 0.94 in, 0.95 in, 0.96 in, 0.97 in, 0.98 in, 0.99 in, 1 in, 1.01 in, 1.02 in, 1.03 in, 1.04 in, 1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in, 1.13 in, 1.14 in, 1.15 in, 1.16 in, 1.17 in, 1.18 in

Insulation Outer Diameter (metric)

23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm

Insulation Rejacketing

Yes

Lug/Stem Connector Included in Kit

No

Maximum Cable Outside Diameter

3.90 in

Maximum Cable Outside Diameter (Metric)

99.1 mm

Maximum Installed Length

8.50 in

Number of Conductors

3

Product Series

7600-T-3G, 7600-3G

Suitable for High Voltage

No

Voltage

5 kV, 8 kV

Voltage Application

Medium Voltage

Resources

Safety Data Sheets

Document Number: MSDS_2654440_CA_EN

(PDF)