  6. 3M™ Scotchlok™ Electrical Insulation Displacement Connector, 905, red, double run or tap, 22-18 AWG (Tap), 18-14 AWG (Run)

3M™ Scotchlok™ Electrical Insulation Displacement Connector, 905, red, double run or tap, 22-18 AWG (Tap), 18-14 AWG (Run)

  • 3M ID 7000021415

Quick and easy connection

No wire stripping needed

Double run or tap

View more details

Details

Highlights
  • Quick and easy connection
  • No wire stripping needed
  • Double run or tap
  • Maximum recommended current for general purpose applications: 18 AWG - 7 Amps, 16 AWG - 10 Amps, 14 AWG - 15 Amps
  • Tap, inline, pigtail, or double run

3M™ Scotchlok™ Electrical Insulation Displacement Connectors electrically connect a tap wire end through a run wire to insulates the connection. These connectors make inline, pigtail and tap splices on 14 gauge solid or stranded wires with no wire stripping. They have a maximum insulation O.D. diameter of 0.145 inches (3.68 millimetre) and an operating temperature of 194 degrees Fahrenheit (90 degrees Celsius). The suggested application tool for this connector is the 3M™ Scotchlok™ Crimping Tool, E-9BM.

The connector insulation is manufactured from polypropylene and is rated for 32V applications. It withstands temperatures of 194 degrees F (90 degrees C). RoHS 2011/65/EU Compliant.

Suggested applications
  • Suitable for inline, pigtail and tap splices
  • Suitable for dry environment applications
  • Insulated copper conductors only

Typical Properties

Brands

Scotchlok™

Conductor Sizes (Imperial)

14 AWG (Run), 18 AWG (Run), 18 AWG (Tap), 22 AWG (Tap)

Conductor Sizes (Metric)

.34 mm² (Tap), 1 mm² (Run), 1 mm² (Tap), 2.5 mm² (Run)

Connection Type

Double Run or Tap

Connector / Connector Tool

3M Crimping Tool E-9BM and/or 9" Lineman's Pliers and/or Mechanics (slip joint) Pliers

Connector Style

Insulation Displacement

Flame Retardant

No

Grease Filling Against Corrosion

No

Insulation Colour

Red

Insulation Material

Polypropylene

Material

Insulator: Polypropylene, U-contact: Tin-plated Copper Alloy

Maximum Conductor Size (Imperial)

14 AWG (Run)

Maximum Conductor Size (Metric)

2.5 mm² (Run)

Maximum Operating Temperature (Celsius)

90 °C

Maximum Operating Temperature (Fahrenheit)

194 null

Maximum Recommended Voltage Rating

32 V

Minimum Conductor Size (Imperial)

18 AWG (Run)

Minimum Conductor Size (Metric)

.34 mm² (Tap)

Moisture Resistant

No

Package Quantity

500

Product Colour

Red

Product Type

Double Run or Tap

Recommended Crimping Tool

E-9BM or 9 in. Linemans Pliers and/or Mechanics (slip joint) Pliers

Run Maximum Insulation Outer Diameter (Imperial)

0.145 in

Run Maximum Insulation Outer Diameter (Metric)

3.7 mm

Tap Maximum Insulation Outer Diameter (Imperial)

0.145 in

Tap Maximum Insulation Outer Diameter (Metric)

3.7 mm

Units per Case

5000.0

Voltage Application

Low Voltage

Manufacturing Origin: USA