3M™ Cold Shrink QT-II Outdoor Termination Kit 5601

  • 3M ID 7000005951
  • UPC 00054007024279

One-piece cold shrink termination.

High dielectric-constant material regulates the distribution of electric field stress

Suitable for outdoor, weather exposed applications

View more details
Frequently viewed resources
PDF (1) Copy 26Safety Data Sheet (PDF)

Details

Highlights
  • One-piece cold shrink termination
  • High dielectric-constant material regulates the distribution of electric field stress
  • Suitable for outdoor, weather exposed applications
  • Silicone rubber insulation is track-resistance and hydrophobic
  • Silicone cold shrink application provides constant radial pressure, "living seal"
  • Withstands voltages of 5 to 15kV and is 110 kV BIL-rated
  • Meets IEEE Standard 48, Class 1 for outdoor, weather-exposed applications

The 3M™ QT-II Cold Shrink Outdoor Termination Kit 5601 includes a 4 skirt, 1 piece termination. It ensures a pliable, tight seal for concentric neutral cables. The conjunction of high dielectric constant material and silicone rubber insulation allows the termination to withstand voltages of 5 to 15kV.

The 3M™ QT-II Cold Shrink Outdoor Termination Kit 5601 consists of a high dielectric constant (Hi-K) stress control tube insulated with a moulded silicone skirted insulator. There is a four-skirt design rated 15 kV, six-skirt design rated 25/28 kV, and an eight-skirt design rated 35kV. They are provided in an expanded state, mounted on a removable inner supporting plastic core.

Suggested applications
  • Used to terminate concentric neutral cables rated 15kV, 25/28 kV, and 35 kV
  • Lightweight for either free-hanging or bracket-mounting arrangements
  • Used in both protected and weather-exposed contaminated areas

Typical Properties

Applications

Cable Termination

BIL

110 kV

Brands

3M™

Breakout Boot

No

Cable Insulation Outside Diameter Range

0.64 to 1.12 in

Cable Insulation Outside Diameter Range (metric)

16.3 to 28.4 mm

Cable Shielding

Concentric Neutral (CN)

Case Quantity

1

Conductor Sizes (Imperial)

1 AWG, 2 AWG, 1/0 AWG, 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil, 300 kcmil, 350 kcmil, 400 kcmil, 500 kcmil

Indoor/Outdoor

Outdoor Skirted

Insulation Level

100%, 133%

Insulation Outer Diameter (Imperial)

0.64 in, 0.65 in, 0.66 in, 0.67 in, 0.68 in, 0.69 in, 0.7 in, 0.71 in, 0.72 in, 0.73 in, 0.74 in, 0.75 in, 0.76 in, 0.77 in, 0.78 in, 0.79 in, 0.8 in, 0.81 in, 0.82 in, 0.83 in, 0.84 in, 0.85 in, 0.86 in, 0.87 in, 0.88 in, 0.89 in, 0.9 in, 0.91 in, 0.92 in, 0.93 in, 0.94 in, 0.95 in, 0.96 in, 0.97 in, 0.98 in, 0.99 in, 1 in, 1.01 in, 1.02 in, 1.03 in, 1.04 in, 1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in

Insulation Outer Diameter (metric)

16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm

Insulation Rejacketing

No

Lug/Stem Connector Included in Kit

No

Maximum Installed Length

8.50 in

Number of Conductors

1

Number of Skirts

4

Product Series

5600

Voltage

5 kV, 8 kV, 15 kV

Resources

Safety Data Sheets

Document Number: MSDS_2632537_CA_EN

(PDF)