3M™ Fire Barrier Watertight Spray

  • Options available
  • | Select product options for IDs.

Seals interior construction voids

Superior washout resistance

Meets UL Water Leakage Test, W-Rating— Class One requirements for systems tested and listed in accordance with ANSI/UL 1479, and and CAN/ULC-S115

View more details
Ask an expert orange background

Ask an expert

Get advice. See if 3M™ building and construction products are right for your project.

Get In Touch

Details

Highlights
  • Seals interior construction voids
  • Superior washout resistance
  • Meets UL Water Leakage Test, W-Rating— Class One requirements for systems tested and listed in accordance with ANSI/UL 1479, and and CAN/ULC-S115
  • Up to 3-hour fire protection in construction joints per ASTM E 1966 (UL 2079)
  • Helps minimize noise transfer (STC Rated)
  • CPVC compatible

3M™ Fire Barrier Watertight Spray is a sprayable, moisture-curing hybrid siliconized polymer that forms a tough, elastomeric coating. This material is used to firestop perimeter joints, like curtain wall joints, and other construction joints that need to prevent fire and water from moving floor to floor.

First Line of Defense 3M™ Fire Barrier Watertight Spray helps control twill act as a barrier to water leakage and airborne sound transmission, while helping to control the transmission of fire, heat and smoke before, during and after exposure to fire. It is a sprayable, moisture-curing hybrid siliconized polymer that forms a tough, elastomeric coating. This material is used to firestop perimeter joints (curtain wall joints) and other construction joints that need to prevent fire and water from moving floor to floor. The spray meets UL Water Leakage Test, W Rating - Class 1 requirements for systems tested and listed in accordance with ANSI/UL 1479 and is tested in accordance with ASTM G 21 standard practice for determining resistance of synthetic polymeric materials to fungi. This spray provides remarkable adhesion on most construction surfaces, including: concrete, gypsum, metal, plastic, wood and insulation. The seal is for interior construction voids such as blank openings, metallic pipes, non-metallic pipes, cables, cable trays, insulated pipes, busways, HVAC vents and ducts, combos and construction joints. Recommended Applications • Firestopping • Smoke sealing • Water sealing The Science of Better Fire Protection from 3M Since 1925 when one of our lab assistants invented masking tape, 3M has been applying science to life -developing adhesive products and technologies that help entire industries and individual businesses worldwide. The work that began with a single 3M engineer now spans decades and generations. And all of it goes into each of our adhesives, sealants, protective coatings, devices and the best ways to used them - including Fire Barrier Pass-Through Device Brackets to improve performance, and to help businesses like yours operate faster, better and more efficiently.

Suggested applications
  • ASTM E 2307 Standard Test Method for Fire Tests of Perimeter Joint Firestop Systems and CAN/ULC-S115 at the maximum extended joint width
  • ASTM E 814/UL 1479 and CAN/ULC-S115 Standard Test Method for Fire Tests of Penetration Firestop Systems

Typical Properties

Resources