Firestop tested for up to three hours in accordance with ASTM E 814 (UL 1479)

Models for metallic (black cap) and non-metallic (white cap) penetrating items

Easily adjusted height accommodates concrete thickness from 2-1/2" up to 8" (57.2 mm to 203.2 mm)

View more details

Details

Highlights
  • Firestop tested for up to three hours in accordance with ASTM E 814 (UL 1479)
  • Models for metallic (black cap) and non-metallic (white cap) penetrating items
  • Easily adjusted height accommodates concrete thickness from 2-1/2" up to 8" (57.2 mm to 203.2 mm)
  • Meets UL Water Leakage Test, W Rating — Class 1 requirements for systems tested and listed in accordance with ANSI/UL 1479 (see system details)
  • UL Classified for two and three hours of fire (F) rating, one and three hours of temperature (T) rating
  • Installs securely by attaching directly to flooring deck
  • Rugged one-piece design to withstand every-day bumps, kicks and hard knocks of the construction process

Designed to provide one-step fire stopping for penetrations through fire-rated concrete floor assemblies, 3M™ Fire Barrier Cast-In Devices for Plastic Pipes are a proven alternative to core drilling holes. Installers simply attach the devices directly to floor decking, pour concrete around them and route penetrants after the concrete cures. Heights are adjustable in half-inch (13 mm) increments.

Simply a Better Way to Firestop Firestopping through concrete used to mean three things: pouring the concrete, core drilling holes, and firestopping later. Our 3M™ Fire Barrier Cast-In Devices for Plastic Pipes eliminate the time and expense of firestopping non-metallic penetrants using extra materials such as pipe devices, intumescent strips and caulk. This allows for a more secure, permanent firestop installation before concrete is poured. A series of built-in tear strips makes for fast, easy height adjustment in ½ inch increments: using only a pliers, installers can quickly adjust the height of the device from its maximum 8 inches (203.2 mm) to as low as 2-1/2 inches (57.2 mm). The device secures easily to floor decking, and its one-piece design withstands the everyday impact and wear of the construction site. Its white cap, easily visible after pour, signifies it as a pass-through device for non-metallic penetrants. Recommended Applications • Firestopping of plastic pipes – ccPVC, PVC, ENT, CPVC, FRPP, PVDF, ccABS, ABS, rigid non-metallic, PEX • For concrete thicknesses from 2-1/2 inches (203.2 mm) to 8 inches (57.2 mm) or higher in conjunction with 3M™ Fire Barrier Cast-In Devices Height Adaptor • In conjunction with 3M™ Fire Barrier Cast-In Device Metal Deck Adaptor for attaching to fluted decks Fully Tested and Approved Our intumescent 3M™ Fire Barrier Cast-In Devices for Plastic Pipes are firestop tested up to 3 hours in accordance with ASTM E 814 (UL 1479). They are UL Classified for 2- and 3-hour fire (F) rating, and 1- and 3-hour temperature (T) rating. They also meet UL Water Leakage Test, W Rating - Class 1 requirements for systems tested and listed in accordance with ANSI/UL 1479 (see system details). Reliable and Affordable Fire Protection Effective and easy to install, 3M™ Fire Barrier Cast-In Devices for Plastic Pipes are part of our family of fire protection products that offer the broadest, long-lasting solutions for a variety of commercial, industrial and residential applications. As a trusted leader in the fire protection industry, 3M offers a broad line of affordable products designed to meet the most demanding firestop requirements. Find the solution you need from the industry-preferred line of fire protection products.

Suggested applications
  • May be applied to two inches non-metallic pipe and HVAC line sets in drain, waste, supply and vented or closed pipe systems
  • Commonly used to firestop ccPVC, PVC, RNC and CPVC pipes penetrating concrete floors with fire-ratings up to three hours
  • Use the appropriately-sized device as listed in system details (black-capped devices for metallic penetrations and white-capped devices for non-metallic penetrations)

Typical Properties