Firestop tested for up to three hours, when used in conjunction with the appropriate 3M™ Fire Barrier Cast-In Device, in accordance with ASTM E 814 (UL 1479)

Easily snaps into place on device without additional fastening

Factory made, helps assure consistent quality

View more details

Details

Highlights
  • Firestop tested for up to three hours, when used in conjunction with the appropriate 3M™ Fire Barrier Cast-In Device, in accordance with ASTM E 814 (UL 1479)
  • Easily snaps into place on device without additional fastening
  • Factory made, helps assure consistent quality
  • UL Classified, universally recognized independent test agency
  • Red colour easily identifiable as fire-rated

3M™ Fire Barrier Cast-In Device Metal Deck Adaptors are one-piece plastic body adaptors for fire stopping on fluted metal decks. Installers simply snap a metallic or non-metallic 3M™ Fire Barrier Cast-In Device into the adaptor – no fasteners are required – and attach it to the metal decking before concrete slabs are poured. Adaptor/device assemblies are firestop tested up to three hours.

Simply a Better Way to Firestop To expand the versatility of our time- and money-saving cast-in firestopping, our 3M™ Fire Barrier Cast-In Device Metal Deck Adaptors let technicians install our 3M™ Fire Barrier Cast-In Devices onto uneven metal fluted decking before concrete slabs are poured. This one-piece plastic adaptor features snap-in attachment to the Fire Barrier Cast-In Device - no tools or fasteners are required. It installs quickly and easily onto fluted steel pan decks for drain, waste and vented or closed pipe systems. The adaptor accepts Cast-In Devices for both plastic and metal pipes. Recommended Applications • Use in conjunction with metallic and non-metallic 3M™ Fire Barrier Cast-In Devices • Fluted steel pan decks for drain, waste, and vented or closed pipe systems • New construction jobs requiring a minimum 2-1/2”(63.5 mm) concrete topping • Consult 3M™ Fire Barrier Cast-In Device Metal Deck Adaptor Installation Guide (supplied with each device) and listed system details for exact type of penetrants covered and hourly ratings Fully Tested and Approved When used in conjunction with Fire Barrier Cast-In Devices in listed systems, 3M™ Fire Barrier Cast-In Device Metal Deck Adaptors are firestop tested up to 3 hours in accordance with ASTM E 814 (UL 1479). The Science of Better Fire Protection from 3M Since 1925 when one of our lab assistants invented masking tape, 3M has been applying science to life -developing adhesive products and technologies that help entire industries and individual businesses worldwide. The work that began with a single 3M engineer now spans decades and generations. And all of it goes into each of our adhesives, sealants, protective coatings, devices and capability-expanding adaptors including 3M™ Fire Barrier Cast-In Device Metal Deck Adaptors to improve performance, and to help businesses like yours operate faster, better and more efficiently.

Typical Properties