3M™ Cold Shrink EPDM rubber insulating sleeve is a factory-expanded tube loaded on a removable plastic core. Simply prepare the connection, position the tube and unwind the core.
3M™ Cold Shrink tubes are open-ended tubular sleeves with a sealing mastic on each end. The core is removed by pulling from one end after the insulating tube has been positioned over an inline connector, allowing the ends of the tube to shrink and form a water-resistant seal. Sizing of the core and tube, along with the sealing mastic on each end, provides a broader application range without degrading the seal and insulating characteristics of the EPDM rubber tube. The live memory action of the specially formulated material ensures a permanent, durable environmental seal and insulation.
Applications | Cable Connection |
Cable Shielding | Non-shielded |
Cable Type | Power Cable |
Case Quantity | 10 |
Conductor Material | Aluminum, Copper |
Conductor Sizes (Imperial) | 1 AWG, 2 AWG, 1/0 AWG, 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil, 300 kcmil, 350 kcmil, 400 kcmil, 500 kcmil, 600 kcmil, 650 kcmil, 700 kcmil, 750 kcmil, 800 kcmil, 900 kcmil, 1000 kcmil, 1250 kcmil |
Conductor Sizes (Metric) | 400 mm², 456 mm² |
Connector Included | None, No |
Dielectric Strength (V/mil) | 365 V/mil |
Elongation | 750 % |
Halogen Free | No |
Indoor/Outdoor | Both |
Inner Diameter After Shrink (Imperial) | 0.4 in, 0.71 in |
Inner Diameter After Shrink (Metric) | 10.2 mm, 18 mm |
Inner Diameter Before Shrink (Imperial) | 1.45 in, 2.25 in |
Inner Diameter Before Shrink (Metric) | 36.8 mm, 57.2 mm |
Insulation O.D. Range | 0.40-1.45 in, 0.71-2.25 in |
Insulation O.D. Range (Metric) | 10.2-36.8 mm, 18.0-57.2 mm |
Insulation Outside Diameter Range | 0.84 - 1.38 Inch, 1.04 - 1.70 Inch |
Insulation Outside Diameter Range (metric) | 21.3 - 35.1 mm, 26.4 - 43.2 mm |
Material | EPDM Rubber |
Maximum Conductor Size (Imperial) | 4/0 AWG, 400 kcmil |
Maximum Conductor Size (Metric) | 95 mm², 185 mm² |
Maximum Connector Length | 4.50 in, 6.00 in |
Maximum Connector Length (metric) | 114.3 mm, 152.4 mm |
Maximum Connector O.D. | 1.45 in, 2.25 in |
Maximum Connector O.D. (Metric) | 36.8 mm, 57.2 mm |
Maximum Operating Temperature (Celsius) | 90 °C |
Maximum Operating Temperature (Fahrenheit) | 194 null |
Minimum Conductor Size (Imperial) | 2 AWG (Aluminum), 250 kcmil (Copper), 250 kcmil (Aluminum) |
Minimum Conductor Size (Metric) | 35 mm² (Aluminum), 120 mm² (Copper), 120 mm² (Aluminum) |
Minimum Operating Temperature (Celsius) | -40 °C |
Minimum Operating Temperature (Fahrenheit) | -40 null |
Model | Cold-shrink |
Number of Conductors | 1 |
Product Type | Splice |
Splice Type | Cold Shrink |
Typical Splice Length | 29 in, 32 in |
Typical Splice Length (metric) | 736 mm, 813 mm |
Units per Case | 1.0 |
Voltage | 1 kV |
Voltage Application | Medium Voltage |
With Inner Glue | No |